VOC environment test equipment

Current location: home page > Product display > VOC environment test equipment >

Vehicle VOC environment warehouse

Vehicle VOC environment warehouse

Original price ¥ yuan

Valence: element

Model No.: v-1000

Scale:

Commodity details common problem Order online


1、 Product use

The standard specifies the determination of volatile organic compounds (VOC) and aldehydes and ketones in furniture, carpet, plastic, rubber, interior decoration, automobile interior decoration, workplace, paint, coating, building and other consumer goods.

2、 Executive Standards

GB 18580-2017 "formaldehyde emission limits of wood based panels and their products for interior decoration and decoration materials"

GB 18580-2001 formaldehyde emission from wood based panels and their products

GB 18584 limits of harmful substances in wood furniture

EN 717-1 environmental chamber method for the measurement of formaldehyde emission from wood based panels

Limit of harmful substances in soft furniture sofa

GB 18587-2001 "indoor decoration materials carpet, carpet liner and carpet adhesive harmful substances" Quality release limit

Ly / t1980-2011 "volatile organic compounds (VOC) and formaldehyde emission test box"

ASTM D6007-02 Standard Test for determination of formaldehyde concentration in wood products by small scale environmental chamber Test method

En13419-1 "determination of VOCs emission from building products Part 1: method of environmental chamber for release test"

ANSI / BIFMA m7.1-2011 standard for VOC release rate in office furniture systems, components and seats Test methods

3. Reference standards:

  ASTM D5116—97

  ASTM D6330—98

  ASTM D6670—01

  ASTM E1333—96

  JIS A1901-2009

  ISO 12460-1.2007

  ISO 16000-9-2011

 
IV. technical indicators

 

Items Technical index
temperature Regulating range: (15 ~ 40) ℃
Adjustment accuracy: ± 0.5 ℃
relative humidity Regulation range: (30-80)% RH
Adjustment accuracy: ± 3% R.H
Air exchange rate Adjustment range: 0.2 M three ~2 m three /h
(air change rate 0.2 ~ 2 times / hour; adjustment accuracy: ventilation rate ± 1%)
Face Velocity The air horizontal velocity is kept at (0.1-0.3) m / s, and the accuracy is less than 0.05 M / s
Test chamber size (tank) (1±0.02)m three
SUS304 mirror stainless steel plate is welded as a whole. The welding area and surrounding area are polished and free of deformation. All edges and corners are made into a certain radian, which can be washed and cleaned by water. There are no rubber, adhesive and other interfering materials, sealing materials and other devices in contact with the air in the test chamber, and do not absorb organic matters and formaldehyde. No condensation or condensation is allowed in the test chamber.
Relative external pressure in test chamber 10±5Pa
Airtightness Static leakage rate: leakage rate ≤ 1 × 10 under 1kPa relative pressure -3 m three /min
Insulation box The thickness of polyurethane insulation board is 60mm, the outer wall is steel plate, white spraying; the inner wall is 304 stainless steel plate
Background concentration The background concentration of formaldehyde is less than 0.006mg/m three The background concentration of TVOC was less than 0.02 mg / M 3. Background concentration of single VOC < 0.002mg/m three
Measurement and control system
 
Real time monitoring and recording the temperature, humidity, pressure, flow, replacement rate, time and other control parameters in the cabin. Touch control screen is used as the dialogue interface of personnel operating equipment, which is intuitive and convenient. The configuration of special control software not only realizes the function of touch screen, but also has remote control function, which can realize system control, program setting, dynamic data display and historical data playback, fault record, alarm setting and other functions.
Structural design The main body adopts the international advanced jacket structure, compact and clear
Clean, efficient, energy-saving, not only reduce energy consumption, but also reduce
The efficiency of detection is reduced and the detection time is improved
Ben.
power The average power of the equipment is 1.5KW and the rated power is 3KW.
External dimension of test chamber Width 1200mm × height 1550mm × length (depth) 1980mm
protection system 1) High voltage protection and over-current protection of refrigeration system
2) Heater over temperature protection
3) Motor over current protection
4) Water shortage protection
5) Air pump overheating, over-current, overpressure protection
6) Protection of power supply under phase and phase sequence
7) Short circuit and over current protection
environment condition 1) Temperature: 5 ℃~ 35 ℃
2) Relative humidity: ≤ 85%
3) Air pressure: 86kpa ~ 106kpa
4) There is no pollution source around
 

5、 Software interface

This machine adopts the integrated touch screen operation, the interface display integration is high, the intelligent operating system can record the user's use habits, the setting is convenient, only need to set a few common parameters, the control system will automatically optimize the adjustment, to achieve the user's set parameters.

Figure 4-2 operation monitoring interface

Serial number name Function / use
(1) Status indicator The main alarm information is displayed in red
(2) information display Equipment operation information window, alarm information display window, prompt operation status, unknown fault.
(3) Screen selection button Enter the operation monitoring screen
(4) Screen selection button Enter the parameter setting screen
(5) Screen selection button Enter the timing setting screen
(6) Lighting switch button Or turn the lights on or off
(7) Running switch The equipment enters the running state or stops running
(9) Run tag Prompt: "run" will be displayed when running, and "stop" will be displayed in stop state
(10) Time display Displays the current time and the time of the test
(11) Temperature display Displays the current temperature in the cabin
(12) Water level status bar The green status bar is full at high water level and empty at low water level
(13) Humidity display Displays the current humidity in the cabin
(14) Curve and other information display You can enter the curve display window by clicking the curve interface
 

 
6、 Safety protection device
The compressor of refrigeration system is overheated, over-current and overpressure, and the condensing fan is overheated
Test box limit over temperature, fan, motor overheat relay
The dry burning, abnormal water supply, drainage and water shortage of humidification heat pipe in the humidification system are abnormal
Power supply leakage protection, overload and short circuit protection
Storage environment requirements: the ambient temperature of the equipment should be kept within 0 ℃ ~ + 35 ℃
 
7、 Environmental conditions for installation
Temperature: 0 ~ 30 ℃;
Atmospheric pressure: 86 ~ 106kpa
There is no strong vibration around;
There is no strong magnetic field around;
There is no high concentration organic matter release source around
Power supply conditions
Voltage: 220 / 380V ± 4%
Frequency: 50 ± 0.5Hz
Current: not less than 50A
Water supply conditions: distilled water with water temperature not higher than 30 ℃
The distance between the left and right and rear wall panels of the test box shall not be less than 800mm from the wall, and the distance between the front wall and the wall shall not be less than 1000mm. When the equipment is transported, whether it can enter the door or passage, elevator, etc., so as to avoid affecting the project progress of your company.
Transportation mode: whole machine transportation
 
8、 Acceptance criteria and third party verification
1. Acceptance criteria: the technical indicators shall be in accordance with the method specified in the "technical agreement" B / t5170-1995 signed by both parties.
2. Acceptance method: formal acceptance shall be conducted on the site of the demander.
3. If the demander needs to invite a third party (verified by the national environmental test equipment quality inspection center and issue the inspection report with validity period) to participate in the acceptance before delivery, the expenses shall be borne by the demander. If the supplier fails to pass the first acceptance, the supplier shall bear the cost.
4. The client entrusts the national environmental test equipment quality inspection center for verification.
  

Related products

  • Function description of each system in constant temperature and humidity test chamber Release time: October 15, 2020

    1、 The refrigeration system of constant temperature and humidity test box is similar to that of household refrigerator. After starting the machine, the temperature and humidity parameters are set. The control system first detects the temperature of the test chamber

  • What is the operation process of vacuum high temperature box? Release time: October 10, 2020

    The correct use method should be first vacuumized and then heated. After reaching the rated temperature, if it is found that the vacuum degree has decreased, the pump should be added properly. It is beneficial to extend the service life of the equipment. ...

  • Cause analysis of slow cooling in constant temperature and humidity test chamber? Release time: September 27, 2020

    Under normal conditions, the constant temperature and humidity test chamber will be cooled to the corresponding value according to the set time. However, due to the equipment used for a long time, or improper operation, it will lead to the slow cooling of the constant temperature and humidity test chamber. ...

  • What is the history of fatigue testing machine? Release time: September 23, 2020

    The earliest static testing machine was mechanical. For example, in England, in 1880, the lever weight type material testing machine was produced, and in 1908, the universal testing machine with nut and screw loading (the prototype of electronic universal testing machine) was produced

  • The 20th Chengdu International Laboratory of scientific instruments and equipment 2020 Release time: August 21, 2020

    The 20th Chengdu International Exhibition of scientific instruments and laboratory equipment and the exhibition of the third party inspection and testing certification institutions + the 26th instrument and measurement control exhibition September 10-12, 2020 Chengdu Century City new country

  • What is the difference between high frequency shaking table and low frequency shaking table? Release time: August 13, 2020

    From the frequency difference: high frequency vibration table, the frequency can reach: 10000 Hz, but below 5 Hz can not reach the low frequency vibration table, the frequency can reach: 2000 Hz, more than 2 kHz frequency can not reach, but can be low

  • What are the VOC test standards for car parts? Release time: July 21, 2020

    1. Standard 1.1, honoh 00942-778 00-2014 (WOC test medium specification for interior Paris) 1.2, 1s012219 z-2012 "interior air of road vehicles: Part 2

  • How does the dust testing machine work? Release time: July 7, 2020

    The sand and dust testing machine is mainly used to simulate the natural bad sand and dust environment, to test the temperature change, dry and wet change, wind speed change, dust deposition and air pressure change, etc

  • Some requirements for vehicle rain test room to meet? Release time: July 3, 2020

    The vehicle rain test room is used to test the water leakage and airtightness of the whole vehicle or parts under different rain intensities, and to test the waterproof performance of automobile products, so as to provide reference for improving products and R & D. ...

  • UV UV aging test box operation guide! Release time: June 2, 2020

    The following points should be paid attention to during UV aging test: 1. 2. In the test stage, the door opening should be reduced as much as possible


Please fill in your needs and contact information, convenient for customer service to contact you!

Order products:
Your name:
contact information:
Contact email:
Region:
Remarks:
    
contact us
 contact us
Weisi instrument

400 Tel: 4000-166-872

contact number: 022-22910499

Company fax: 022-22910499

phone number: eighteen billion six hundred and twenty-two million five hundred thousand eight hundred and thirty-seven

Customer service QQ: one billion fifty-three million three hundred and sixty-four thousand six hundred and ninety-nine

Email: chinaweisi@tsflthm.com

Address: No.1 xixiaozhuang Industrial Zone, chagugang Town, Wuqing District, Tianjin

[up] ?
Online Service

Online consultation

Online consultation

Online consultation

Telephone number:
022-22910499
 QR code

Wechat service platform